Safety Instructions
Once the drive has been installed, the person responsible for
installation has to issue an EU Conformity Declaration for the
door system in accordance with Machine Directive 98/37/EG as
well as fitting the CE seal and the rating plate.
This also applies to doors installed for private purposes and in
cases where the drive has been retrofitted to a manual door.
These Instructions as well as the drive's Installation and
Operating Instructions should be kept by the user for reference
purposes.
The force setting is relevant to the system's safety and must
therefore be carried out with due care and attention. An exces-
sively high force setting can injure people and/or animals and
damage property.
Select as low a force setting as possible to ensure that obstacles
are identified in a fast, safe manner.
Risk of sudden closing or opening!
When the emergency release is actuated, the door might
suddenly be opened or closed, due to a damaged spring or
incorrect balance weight. This might damage or even destroy
the drive unit.
Setting door OPEN + CLOSED final
travel positions
While adjusting the settings, open and close the gate manually.
Do not operate it with the engaged drive system.
The distance over which the drive mechanism moves the door can be
increased/reduced by using the cut-out buffer (V + H).
Check that the door opens and closes completely. If it does not, its travel
must be adjusted.
Door CLOSED final travel position
Release the trolley. Pull the emergency release rope (N) once. It
must be possible to slide the trolley back and forth by hand.
Close the door by hand.
Release the switch trigger (V) and slide it towards the trolley until it
triggers the limit switch. Secure the switch trigger (V) with screws in
this position.
Door OPEN final travel position
Open the door by hand.
Release the switch trigger (H) and slide it towards the trolley until it
triggers the limit switch. Secure the switch trigger (H) with screws in
this position.
Close the door by hand.
Lock the trolley (1):
Pull the emergency release rope (N) once. Move the trolley by hand a
little bit forward until the chain wheel engages with a loud clicking
sound.
V
N
1
H
N
1
Teaching in drive
Whenever the door “opens” or “closes”, the control unit automatically reads
in the force required and memorises it when the end position is reached.
Plug in power plug
The first movement of the drive after the power is connection
must be “door OPEN”. If this is not the case, exchange the wires
to terminals 3+ 4 (sprint/duo) or terminals 12 + 13 (marathon).
Press the push-button (1). The door is opened to limit position
"door OPEN".
Close gate, press button (1).
Reset the control unit
Carry out control reset in accordance with the procedure for the
given drive type. See 'Operation / Handling' section.
Carry out following procedure twice:
Press push-button (1) once
Door opens as far as cut-off buffer (H)
Lamp (2) starts to flash
Press push-button (1) once
Door closes as far as cut-off buffer (V)
Lamp (2) starts to flash
When all force values are read and saved, the lamp (2) ceases flashing.
The operator has been 'taught' successfully!
Checking the limit positions for door
OPEN + CLOSED
The trolley of the drive system can be extended or shortened by means of
the switch triggers.
Check whether the door is opening and closing properly. If this is not the
case, adjust the trolley.
Actuate the control device (e.g. push-button, remote control device,
etc.) once.
The door is opened.
If it fails to reach the desired limit positions for door OPEN + CLOSED,
readjust the limit positions. For detailed instructions, see chapter “Adjusting
door OPEN + CLOSED settings”.
1
2
2
2
1
1
2
Commissioning