Marathon MAGNUM ROUTER Instrukcja Operatora Strona 30

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 60
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 29
30
setting is prevented.
VOLTAGES AT RECEPTACLES
277/480V 3-PHASE
Switch styles vary by model.
L1-L2 = 480V L1-N = 277V N =
L2-L3 = 480V L2-N = 277V
L3-L1 = 480V L3-N = 277V
277/
480V
120/
208V
RECEPTACLE L-L L-N
GFCI - 139V
GFCI w/Buck - 120V
Twist-locks 240V 139V
00083
L1-L2 = 208V L1-N = 120V N =
L2-L3 = 208V L2-N = 120V
L3-L1 = 208V L3-N = 120V
VOLTAGES AT RECEPTACLES
120/208V 3-PHASE
Switch styles vary by model.
RECEPTACLE L-L L-N
GFCI - 120V
GFCI w/Buck - 120V
Twist-locks 208V 120V
277/
480V
120/
208V
120/
240V
00085
L1-L2 = 240V L1-N = 120V N =
L2-L3 = 240V L2-N = 208V
L3-L1 = 240V L3-N = 120V
VOLTAGES AT RECEPTACLES
120/240V 3-PHASE
Switch styles vary by model.
RECEPTACLE L-L L-N
GFCI - 120V
GFCI w/Buck - 120V
Twist-locks 120V 0/120V
120/
240V 3PH
277/
480V
120/
208V
120/
240V
1PH
4 Position Voltage Selector Switch Option
00086
L1-L2 = - L1-N = 120V N =
L2-L3 = - L2-N = -
L3-L1 = 240V L3-N = 120V
VOLTAGES AT RECEPTACLES
120/240V 1-PHASE
Switch styles vary by model.
RECEPTACLE L-L L-N
GFCI - 120V
GFCI w/Buck - 120V
Twist-locks 240V 120V
120/
208V
120/
240V
00087
= Not recommended for normal use.